Pricing & AvailabilitySRW-65 SERIES
 

<< Back to main

65 WATTS

 

SRW-65 SERIES

     

 OUTPUT SPECIFICATIONS 
Features
  • Universal 85-264 VAC Input
  • High Efficiency
  • Advanced SMT Design
  • Compact 4.0" X 6.0" X 1.1" Size
  • Class B Emissions Per EN 55022
  • 2 Year Warranty
  • Fits 1U Application
  • EN 60950 ITE Certification
  • One to Four Outputs
  • Optional Chassis & Cover

Total Output Power at 500 C65 W
Output Voltage CenteringOutput 1: +/-0.25%
Output 2: +/-5.00%
Output 3: +/-5.00%
Output 4: +/-5.00%
(All outputs at 50% rated load)
Source RegulationOutputs 1-4: 0.5%
Load Regulation
Output 1:1% (10-100% Load Change)
Output 2: 5.0% (20-80% Load Change)
Output 3: 5.0% (20-80% Load Change)
Output 4: 5.0% (20-80% Load Change)
Cross RegulationOutput 2: 5.0%
Output 3: 2.0%
Output 4: 5.0%
(Output 1 load varied 50-100%))
Output Voltage Adjust RangeOutput 1: 95% to 105%
Output NoiseOutputs 1-4: 1%
  
Turn On OvershootNone
Transient ResponseOutputs 1-4
Volt. Deviation 5%
Recovery Time 2 mS
Load Change 50% To 100%
Output Overvoltage Protection (Optional)Output 1: 110% to 150%%
Output Overpower ProtectionOutput 1-4  110% Min.
Outputs cycle on/off, auto recovery
Hold Up Time16 mS Min, 65 W Output
120 V Inputt
Start Up Time1 Second
  INPUT SPECIFICATIONSS 
Source Voltage85-264 Voltage AC
Frequency Range47-63 Hz
Source Current 
True RMS1.5A At 85V Inputut
Peak Inrush40A
Efficiency.72 -.80 (Varies by model)
  ENVIRONMENTALAL SPECIFICATIONS 
Ambient Operating Temperature Range0oC to +70oC Derating: See Power Rating Chart
Ambient Storage Temperature Range-40oC to +85oC
Temperature CoefficientOutputs 1-4: 0.02%/oC
Conducted EmissionsEN 55022 Class B

 
  SAFETY SPECIFICATIONSNS 
  GENERAL SPECIFICATIONS 
General Protection Class:

I

Overvoltage Category:

II

Pollution Degree:

2

Underwriters
Laboratories
File E137708
UL 60950, Third Edition 
UL Recognition Mark for Canada
File E137708
CAN/CSA-C22.2 No. 60950:00 
TUVEN 60950:2000 
 Low Voltage Directive 
Dielectric Strength 
Reinforced Insulation4242 VDC, Primary to Secondary, 1 Sec.
Basic Insulation2121 VDC, Primary to Ground, 1 Sec.
Operational Insulation500 VDC, Secondary to Ground, 1 Sec.
Mean Time Between Failures150,000 Hours min., MIL-HDBK-217F, 25oC, GB
Weight1.65 Lbs.  Chassis and Cover
0.80 Lbs.  Open Frame
  MODEL LISTING
ModelOutput 1Output 2Output 3Output 4
SRW-65-4001+5V/5A-5V/3A+12V/2A-12V/2A
SRW-65-4002+5V/5A+12V/1A+12V/2A-12V/2A
SRW-65-4003+5V/5A+24V/1A+12V/2A-12V/2A
SRW-65-4004+5V/5A-5V/3A+15V/2A-15V/2A
SRW-65-4005+5V/5A+24V/1A+12V/2A-5V/2A
SRW-65-4006+5V/5A+24V/1A+15V/2A-15V/2A
SRW-65-4007+5V/5A+26V/1A+15V/2A-15V/2A
SRW-65-4008+5V/5A+24V/1A+12V/2A-12V/2A
SRW-65-4009+5V/7.5A+8V/.25A+15V/1A-15V/1A
SRW-65-4103+5V/5A26V/1A+12V/2A-12V/2A
SRW-65-4104+5V/4A5V/.25A+15V/2.5A24V/.5A
SRW-65-3001+5V/5A +12V/3A-12V/1A
SRW-65-3002+5V/7A +12V/2A-12V/2A
SRW-65-3003+5V/7A +15V/2A-15V/2A
SRW-65-3004+5V/5A-5V/4A+12V/2A 
SRW-65-3005+5V/5A-5V/4A+24V/1A 
SRW-65-3006+5.25V/6A+15V/1A+34V/1.5A 
SRW-65-2001+5V/7A  -5V/5A
SRW-65-2002+5V/7A +12V/3A 
SRW-65-2003+12V/3A  -12V/2.5A
SRW-65-2004+15V/2.5A  -15V/2A
SRW-65-2005+5V/7A +24V/1.5A 
SRW-65-2006+5V/9A +12V/2A 
SRW-65-2008+6V/5A  -6V/5A
SRW-65-10015V/13A   
SRW-65-100212V/5.4A   
SRW-65-100315V/4.3A   
SRW-65-100424V/2.7A   
SRW-65-100518V/3.6A   
SRW-65-100624V/3.33A   
SRW-65-110521V/3.1A   
  Notes
 Consult factory for alternate output configuration.
Consult factory for positive, negative or floating output 2.
Refer to Application Information for complete output power ratings.
All specifications are maximum at 25C unless otherwise stated and are subjected to change without notice.
Specify optional chassis and cover, overvoltage protection, transient protection or DC Input when ordering.

TUV only:SRW-65-2008
UL, CUL only: SRW-65-1105, SRW-65-4103
  SRW-65 SERIES MECHANICAL SPECIFICATIONS 

  APPLICATIONS INFORMATION
  1. Each output can deliver its rated current but total output power must not exceed
    65 watts. 
     
  2. Semiconductor case temperature must not exceed 110 C
  3. Sufficient area must be provided around convection cooled power supplies to allow natural movement of air develop.
  4. This product is intended for use as a professionally installed component within information technology and medical equipment.
  5. A minimum load of 10% is required on output one to insure proper regulation of remaining outputs.  
  6. Peak to peak output ripple and noise is measured directly at the output
    terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth.
     
  7. This product was type tested and safety certificated using the the dielectric strength test voltages listed in Table V of UL 60950. In consideration of clause 5.2.2, care must be taken to insure the voltage applied to a reinforced insulation does not over stress basic insulation. Secondary to ground capacitors may need to be removed prior to performing a dielectric strength type test on the end product. It is highly recommended that the DC test voltages be used when performing a production-line dielectric strength test of the assembled end product. Please consult factory for further information.
 
  1. This power supply has been safety approved and final tested using a DC
    dielectric strength test. Please consult factory before performing AC dielectric strength test.
  2. Maximum screw penetration into mounting holes is .250 inches
 

 Maximum Output Power vs. Ambient Temperature

 
  CONNECTOR SPECIFICATIONS
TB1AC Input.156 friction lock header mates with Molex 09-50-3051 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
TB2DC Output.156 friction lock header mates with Molex 09-50-3101 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
GGround.187 quick disconnect terminal.
  RECOMMENDED AIR FLOW DIRECTION
  1. Optimum
  2. Good
  3. Fair