 OUTPUT SPECIFICATIONS 
Features
  • Universal 85-264 VAC Input
  • High Efficiency
  • Compact 3.3" X 5" X 1.5" Size
  • Class B Emissions Per EN 55022/11
  • EMC to EN 61000-6-2 & EN 60601-1-2
  • 2 Year Warranty
  • One to Four Tightly Regulated Outputs
  • EN 60950 ITE Certification
  • EN 60601-1 Medical Certification
  • Optional Perforated Cover

Total Output Power at 50o C70W Convection Cooled
85W  Convection Cooled w/1 Sq.ft. baseplate
100W LFM Foreced Air
Output Voltage CenteringOutput 1:         +/-0.25%
Output 2:(SRW) +/-0.25%
             (SRP)  +/-5.0%
Output 3:          +/-2.0%
Output 4:          +/-2.0%
(All outputs at 50% rated load)
Source RegulationOutputs 1-4: 0.5%
Load RegulationOutput 1:0.5% (10-100% Load Change)
Output 2: (SRW) 0.5% (10-100% Load Change)
(SRP)  5.0% (10-100% Load Change)
Output 3: 1.0% (10-100% Load Change)
Output 4: 1.0% (20-100% Load Change)
Cross RegulationOutput 2: (SRW) 0.2% Output 1 load varied 50-100%
(SRP)  5.0%
Output 3:            0.2%
Output 3:            0.2%
Output Voltage Adjust Range Output 1: 95-105%
               85-105% (1001,1004)
 Output 2: 95-105% (SRW models only)
Output NoiseOutputs 1-4: 1%
Turn On OvershootNone
Transient Response  Outputs 1-4
Voltage Deviation 5.0%
Recovery Time     2mS
Load Change       50% to 100%
Output Overvoltage Protection (Optional)Output 1: 110% to 150%
Output Overpower ProtectionOutputs 1 & 2:     110% Min
Outputs cycle on/off, auto recovery
Output Overcurrent ProtectionOutputs 3 & 4:     110% Min
Hold Up Time10 mS min., 100W, 120V Input
Start Up Time 1 Second
  GENERAL SPECIFICATIONS 
Dielectric Strength 
Reinforced Insulation5656 VDC, Primary to Secondary, 1 Sec.
Basic
Insulation
2121 VDC, Primary to Ground, 1 Sec.
Operational Insulation707 VDC, Secondary to Ground, 1 Sec.
Leakage Current<500 A Earth Leakage Current
Power Fail Signal
(optional)
Logic low with input power failure 2mS minimum prior to output 1 dropping 1%
Remote Sense (single output models only)250mV compensation of output cable losses
Mean Time Between Failures150,000 Hours min., MIL-HDBK-217F, 25oC, GB
Weight1.00 Lbs.  Chassis
1.05 Lbs.  Chassis/Cover
  INPUT SPECIFICATIONS 
Source Voltage85-264 Volts AC
Frequency Range47-63 Hz
SourceCurrent
True RMS
Peak Inrush

3A at 85V Input
30A
Efficiency.68-.84 (Varies by model)
  ENVIRONMENTAL SPECIFICATIONS 
Ambient Operating Temperature Range0oC to +70oC Derating: See Power Rating Chart
Ambient Storage Temp. Range-40oC to +85oC
Temperature CoefficientOutputs 1-4: 0.02%/oC

 
 ELECTROMAGNETIC COMPATIBILITY
Electrostatic DischargeEN 61000-4-2+/-8kV Contact Discharge
+/-8kVAir Discharge
Radiated Electro-magnetic Field EN 61000-4-380MHz-2.5GHz, 10V/m, 80% AM
EFT/BurstsEN 61000-4-4+/-2kV
SurgesEN 61000-4-5+/-1 kV Differential Mode
+/-2 kV Common Mode
Conducted ImmunityEN 61000-4-6.15-80MHz., 10V, 80% AM
Voltage Dips and InterruptionsEN 61000-4-1130% Reduction
95% Reduction
60% Reduction
95% Reduction
Radiated EmissionsEN 55011/22Class B
Conducted EmissionsEN 55011/22Class B
Harmonic Current EmissionsEN 61000-3-2 
Voltage Fluctuations and FlickerEN 61000-3-3 
  MODEL LISTING
Model NO.Output 1Output 2Output 3Output 4
SRW-100-4001+3.3V/10A(2)+5V/4A+12V/2A(3)-12V/1A
SRW-100-4002+5V/10A(2)+24V/2A+12V/2A(3)-12V/1A
SRW-100-4003+5V/10A(2)+24V/2A+15V/2A(3)-15V/1A
SRW-100-4004+5V/10A(2)-5.2V/4A+12V/2A(3)-12V/1A
SRW-100-4005+5V/10A(2)-5.2V/4A+15V/2A(3)-15V/1A
SRW-100-4006+5V/10A(2)+3.4V/4A+9V/1A24V/0.5A
SRW-100-4007+5V/10A(2)+15V/3A+12V/2A(3)-12V/1A
SRW-100-4008+5V/10A(2)3.3V/4A+12V/2A(3)-5V/1A
SRW-100-4009-IT+3.3V/10A(2)+5V/4A+12V/2A(3)-5V/1A
SRW-100-4010+5V/5A+15V/4A+12V/2A(3)9V/2.5A
SRW-100-4011+5V/10A(2)-15V/2.2A+15V/2.2A(3)12V/1A
SRW-100-4012+5V/10A(2)3.3V/4A+12V/2A(3)-12V/1A
SRW-100-3001+5V/10A(2)+12V/4A -12V/1A
SRW-100-3002+5V/10A(2)+15V/3A -15V/1A
SRW-100-3003+5V/10A(2)+3.3V/8A -12V/1A
SRW-100-3004+3.3V/10A+5.8V/3A -48V/1A
SRW-100-2001+12V/5A-12V/4A  
SRW-100-2002+15V/5A-15V/3A  
SRW-100-2003+12.5V/4A+16V/2A  
SRW-100-10013.3V/20A(4)   
SRW-100-10025V/20A   
SRW-100-100312V/8.3A   
SRW-100-100415V/6.7A   
SRW-100-100524V/4.2A   
SRW-100-100628V/3.6A   
SRW-100-100748V/2.1A   
SRW-100-100840V/2.5A   
SRP-100-4001+5V/12A(2)+24V/3A+12V/2A(3)-12V/1A
SRP-100-4002+5V/12A(2)+24V/3A+15V/2A(3)-15V/1A
SPR-100-4003+5V/12A(2)-5V/4A+12V/2A(3)-12V/1A
SRP-100-4004+5V/12A(2)-5V/4A+15V/2A(3)-15V/1A
SRP-100-4005+5V/12A+12V/3A+8V/2A-8V/1A
SRP-100-3001+5V/12A(2)+12V/4A -12V/1A
SRP-100-2001+5V/12A(2)+24V/3A  
  Notes 
Consult factory for alternate output configurations.
Consult factory for positive, negative or floating outputs. Refer to Application Information for complete output power ratings.
All specifications are maximum at 25o C unless otherwise stated and are subjected to change without notice. Specify optional perforated cover, power fail, overvoltage protection, isolated output 2, isolated output 4 or DC Input when ordering.
  SAFETY SPECIFICATIONS 
General Protection Class:

I

Overvoltage Category:

II

Pollution Degree:

2

Underwriters
Laboratories
File E137708
UL 60950, Third Edition
UL 2601 - 1 Second Edition
CB Report Per IEC 950 (1991)
Second Edition A1, A2, A3, A4
All EN 60950 Deviations
CB Report Per IEC 601-1-(1988)
First Edition, A1, A2
 
UL Recognition Mark for Canada
File E137708
CAN/CSA-C22.2 No. 60950:00
CAN/CSA-C22.2 No. 601-1-M90
 
TUVEN 60950:2000
EN 60601-1/A2: 1995
 
 Low Voltage Directive 
  SRW/SRP-100 SERIES MECHANICAL SPECIFICATIONS 

  APPLICATIONS INFORMATION
  1. Each output can deliver its rated current but total output power must not exceed 70, 85 or 100 watts as determined by cooling method.
  2. Rated 8A with convection cooling.
  3. Rated 1A with convection cooling.
  4. Rated 50 watts maximum output power when convection cooled, 70 watts when baseplate or forced air cooled.
  5. Free air convection cooling, 70 watts maximum output power.
  6. Base plate cooling rating of 85 watts requires a one square foot.09 thick aluminium area attached to bottom four mounting holes.
  7. Forced air cooling rating of 100 watts requires an air speed of 200 linear feet per minute flowing past a point one inch above the main isolation transformer.
  8. Semiconductor case temperatures must not exceed 110o C.
  9. Sufficient area must be provided around the convection cooled power supplies to allow natural movement of air to develop.
  10. This product is intended for use as professionally installed component within information technology and medical equipment.
  11. A minimum load of 10% is required on output one to ensure proper regulation of remaining outputs.
  12. Remote sense terminals may be used to compensate for cable losses up to 250mV. The use of twisted pair is recommended as well as a decoupling capacitor (0.1-10F) and a capacitor of 100F /amp connected across the load side.
  13. Peak to peak output ripple and noise is measured directly at the output
    terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth.
  14. This product includes only one fuse in the input circuit. In consideration of Clause 57.6 of UL 2601-1, a second fuse may be required in the
    end product.
  15. This power supply has been safety approved and final tested using a DC dielectric strength test. Please consult factory before performing an AC dielectric strength test.
  16. Maximum screw penetration into chassis mounting holes is .125 inches.
  RECOMMENDED AIR FLOW DIRECTION
  1.Optimum  2.Good  3.Fair
 
  1. This product was type tested and safety
    certificated using the the dielectric
    strength test voltages listed in Table V
    of UL 60601-1. In consideration of clause
    20.4g, care must be taken to insure the
    voltage applied to a reinforced insulation
    does not over stress basic insulation.
    Secondary to ground capacitors may
    need to be removed prior to performing
    a dielectric strength type test on the
    end product. It is highly recommended
    that the DC test voltages listed in DVB.1.
    Annex DVB are not exceeded during
    a production-line dielectric strength
    test of the assembled end product.
    Please consult factory for
    further information.
 

 Maximum Output Power vs. Ambient Temperature

  CONNECTOR SPECIFICATIONS
P1AC Input
(Single)
Terminal block with 4-40 screws on 0.325 inch centers mates with #4 spade terminals.
P1AC Input
(Multiple)
.156 friction lock header mates with Molex 09-50-3031 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
P2DC Output(Single)6-32 screw down terminal mates with #6 ring tongue terminal.(10 in-lb max.)
P2DC Output(Multiple).156 friction lock header mates with Molex 09-50-3101 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
GGround.187 quick disconnect terminal.
P3P.F./Sense(Single).100 friction lock header mates with Molex 22-55-2047 or equivalent crimp terminal housing with Molex 6459 or equivalent crimp terminal.
P3P.F./Sense(Multiple) .100 friction lock header mates with Molex 50-57-2027 or equivalent crimp terminal housing with Molex 6459 or equivalent crimp terminal.