Pricing & AvailabilitySRP-40A SERIES
 

<< Back to main

40 WATTS

 

SRP-40A SERIES

     

 OUTPUT SPECIFICATIONS 
Features
  • Universal 85-264 VAC Input
  • High Efficiency
  • Advanced SMT Design
  • Compact 2.5" X 4.25" X 1.2" Size
  • Class B Emissions Per EN 55022/11
  • EMC to EN 61000-6-2 & EN 60601-1-2
  • 2 Year Warranty
  • Fits 1U Application
  • EN 60950 ITE Certification
  • EN 60601-1 Medical Certification
  • Optional Chassis & Cover

Total Output Power40 W (33W, 1001)
Output Voltage Centering(50% Load)Output 1: +/-0.25%
Output 2: +/-5.00%
Output 3: +/-3.00%
Output 4: +/-3.00%
(All outputs at 50% rated load)
Source RegulationOutputs 1-4: 0.5%
Load Regulation (Local Sense)  
Output 1:0.5% (10-100% Load Change)
Output 2: 5.0% (30-100% Load Change)
(2003, 4002) 7.0% (30-100% Load Change)
 
Output 3: 0.5% (10-100% Load Change)
Output 4: 0.5% (10-100% Load Change)
Cross RegulationOutput 2: 5.0%
Output 3: 0.5%
Output 4: 0.5%
(Output 1 load varied 50-100%)
Output Voltage Adjust Range Output 1: 95% to 105%
Output NoiseOutputs 1-4: 1%
  
Turn On OvershootNone
Transient ResponseOutputs 1-4
Volt. Deviation 5%
Recovery Time 2 mS
Load Change 50% To 100%
Output Overvoltage Protection (Optional)Output 1: 110% to 150%
Output Overpower ProtectionOutput 1&2  110% Min.
Outputs cycle on/off, auto recovery
Output Overcurrent ProtectionOutput 3&4      110% Min.
Hold Up Time10 mS Min, 40 W Output
120 V Input
Start Up Time1 Second
  INPUT SPECIFICATIONS 
Source Voltage85-264 Voltage AC
Frequency Range47-63 Hz
Source Current 
True RMS1A At 85V Input
Peak Inrush30A
Efficiency.66 -.72 (Varies by model)
  ENVIRONMENTAL SPECIFICATIONS 
Ambient Operating Temperature Range0oC to +70oC Derating: See Power Rating Chart
Ambient Storage Temperature Range-40oC to +85oC
Temperature CoefficientOutputs 1-4: 0.02%/oC

 
  SAFETY SPECIFICATIONS 
  GENERAL SPECIFICATIONS 
General Protection Class:

I

Overvoltage Category:

II

Pollution Degree:

2

Underwriters
Laboratories
File E137708
UL 60950, Third Edition
UL 2601 - 1 Second Edition
CB Report Per IEC 950 (1991)
Second Edition A1, A2, A3, A4
All EN 60950 Deviations
CB Report Per IEC 601-1-1988
First Edition, A1, A2
 
UL Recognition Mark for Canada
File E137708
CAN/CSA-C22.2 No. 60950:00
CAN/CSA-C22.2 No. 601-1-M90
 
TUVEN 60950/A11:1997
EN 60601-1/A2: 1995
 
 Low Voltage Directive 
Dielectric Strength 
Reinforced Insulation5656 VDC, Primary to Secondary, 1 Sec.
Basic Insulation2121 VDC, Primary to Ground, 1 Sec.

Operational Insulation

707 VDC, Secondary to Ground, 1 Sec.
Leakage Current<300 A Earth Leakage Current
Mean Time Between Failures100,000 Hours min., MIL-HDBK-217F, 25oC, GB
Weight0.85 Lbs.  Chassis and Cover
0.49 Lbs.  Open Frame
 ELECTROMAGNETIC COMPATIBILITY
Electrostatic DischargeEN 61000-4-2+/-8kV Contact Discharge
+/-8kVAir Discharge
Radiated Electro-magnetic Field EN 61000-4-380MHz-2.5GHz, 10V/m, 80% AM
EFT/BurstsEN 61000-4-4+/-2kV
SurgesEN 61000-4-5+/-1 kV Differential Mode
+/-2 kV Common Mode
Conducted ImmunityEN 61000-4-6.15-80MHz., 10V, 80% AM
Voltage Dips and InterruptionsEN 61000-4-1130% Reduction
95% Reduction
60% Reduction
95% Reduction
Radiated EmissionsEN 55011/22Class B
Conducted EmissionsEN 55011/22Class B
  Notes 
Consult factory for alternate output configuration.
Consult factory for positive, negative or floating output 2 or 3.
Refer to Application Information for complete output power ratings.

All specifications are maximum at 25C unless otherwise stated and are subjected to change without notice.
Specify optional chassis and cover when ordering.
  MODEL LISTING
ModelOutput 1Output 2Output 3Output 4Max Power
SRP-40A-4001+3.3V/5A+5V/3A+12V/.7A-12V/.7A40W
SRP-40A-4002+5V/5A+3.3V/3A+12V/.7A-12V/.7A40W
SRP-40A-4003+5V/5A-5V/3A+12V/.7A-12V/.7A40W
SRP-40A-4004+5V/5A-5V/3A+15V/.7A-15V/.7A40W
SRP-40A-4005+5V/5A+24V/1.5A+12V/.7A-12V/.7A40W
SRP-40A-4006+5V/5A+24V/1.5A+15V/.7A-15V/.7A40W
SRP-40A-3001+5V/5A+12V/2A-12V/.7A 40W
SRP-40A-3002+5V/5A+15V/2A-15V/.7A 40W
SRP-40A-2001+5V/5A+24V/1.5A  40W
SRP-40A-2002+5V/5A+12V/3A  40W
SRP-40A-2003+5V/5A-5V/4A  40W
SRP-40A-2004+12V/3A-12V/3A  40W
SRP-40A-2005+15V/2.5A-15V/2A  40W
SRP-40A-10013.3V/10A   33W
SRP-40A-10025V/8A   40W
SRP-40A-100312V/3.33A   40W
SRP-40A-100415V/2.67A   40W
SRP-40A-100524V/1.67A   40W
SRP-40A-100648V/0.83A   40W

 

  SRP-40A SERIES MECHANICAL SPECIFICATIONS 

  APPLICATIONS INFORMATION
  1. Each output can deliver its rated current but total output power must not exceed
    40 watts(33W, 1001). 
  2. Maximum ambient temperature is reduced to 40 C with optional chassis and cover.
  3. Semiconductor case temperature must not exceed 110 C
  4. Sufficient area must be provided around convection cooled power supplies to allow natural movement of air develop.
  5. This product is intended for use as a professionally installed component within information technology and medical equipment.
  6. A minimum load of 10% is required on output one to insure proper regulation of remaining outputs.
  7. Remote sense terminals may be used to compensate for cable losses up to 250mV. The use of a twisted pair is recommended as well as a decoupling capacitor (0.1 0 10microF) and a capacitor of 100microF/amp connected across the load.
  8. Peak to peak output ripple and noise is measured directly at the output
    terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth.
  9. This product is use only one fuse in the input circuit. In consideration of clause 57.6 of UL 2601-1, a second fuse may be required in the end product.
  10. This product was type tested and safety certificated using the the dielectric strength test voltages listed in Table V of UL 60601-1. In consideration of clause 20.4g, care must be taken to insure the voltage applied to a reinforced insulation does not over stress basic insulation. Secondary to ground capacitors may need to be removed prior to performing a dielectric strength type test on the end product. It is highly recommended that the DC test voltages listed in DVB.1. Annex DVB are not exceeded during a production-line dielectric strength test of the assembled end product. Please consult factory for further information.
 
  1. This power supply has been safety approved and final tested using a DC
    dielectric strength test. Please consult factory before performing AC dielectric strength test.
 

 Maximum Output Power vs. Ambient Temperature

  CONNECTOR SPECIFICATIONS
P1AC Input.156 friction lock header mates with Molex 09-50-3031 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
P3DC Output(Single).156 friction lock header mates with Molex 09-50-3061 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
P3DC Output(Multiple).156 friction lock header mates with Molex 09-50-3081 or equivalent crimp terminal housing with Molex 08-50-0189 or equivalent crimp terminal.
P4,5

Sense

.100 friction lock header mates with Molex 22-01-2027 or equivalent crimp terminal housing with Molex 08-50-01114 or equivalent crimp terminal.
GGround.187 quick disconnect terminal.
  RECOMMENDED AIR FLOW DIRECTION
  1. Optimum
  2. Good
  3. Fair