Pricing & AvailabilitySRP-30/35 SERIES
 

<< Back to main

35 WATTS

 

SRP-30/35 SERIES

     

 OUTPUT SPECIFICATIONS 
Features
  • Universal 85-264 VAC Input
  • High Efficiency
  • Advanced SMT Design
  • Compact 3.0" X 6.0" X 2.0" Size
  • Class B Emissions Per EN 55022/11
  • EMC to EN 61000-6-2 & EN 60601-1-2
  • 2 Year Warranty
  • UL Listed
  • One to Four Outputs
  • EN 60950 ITE Certification
  • EN 60601-1 Medical Certification
  • Optional Chasis & Cover



 

  INPUT SPECIFICATIONS 
Source Voltage85-264 Voltage AC
Frequency Range47-63 Hz
Source Current 
True RMS1A At 85V Input
Peak Inrush30A
Efficiency.66 -.80 (Varies by model)

 
  ENVIROMENTAL SPECIFICATIONS 
Ambient Operating Temperature Range0oC to +70oC Derating: See Power Rating Chart
Ambient Storage Temperature Range-40oC to +85oC
Temperature CoefficientOutputs 1-4: 0.02%/oC
 

 

Total Output Power28-35 W (20W, 1001) Medical Dependent
Output Voltage CenteringOutput 1: +/-0.25%
Output 2: +/-5.00%
Output 3: +/-3.00%
Output 4: +/-3.00%
(All outputs at 50% rated load)
Source RegulationOutputs 1-4: 0.5%
Load Regulation (Local Sense)  
Output 1:7% (0-100% Load Change)
(1001) 10.0% (0-100% Load Change)
(4001) 12.0% (0-100% Load Change)
(Remote Sense) 0.5% (0-100% Load Change)
Output 2: 5.0% (30-100% Load Change)
(4001,3 & 4) 10.0% (30-100% Load Change)
(2003, 4002) 12.0% (30-100% Load Change)
Output 3: 1.0% (0-100% Load Change)
Output 4: 1.0% (0-100% Load Change)
Cross RegulationOutput 2: 5.0%
Output 3: 0.5%
Output 4: 0.5%
(Output 1 load varied 50-100%)
Output Voltage Adjust Range Output 1: 95% to 105%
Output NoiseOutputs 1-4: 1%
  
Turn On OvershootNone
Transient ResponseOutputs 1-4
Volt. Deviation 5%
Recovery Time 2 mS
Load Change 50% To 100%
Output Overvoltage Protection (Optional)Output 1: 110% to 150%
Output Overpower ProtectionOutput 1&2  110% Min.
Outputs cycle on/off, auto recovery
Output Overcurrent ProtectionOutput 3&4      110% Min.
Hold Up Time12 mS Min, 28-35 W Output
120 V Input
Start Up Time1 Second

 
  SAFETY SPECIFICATIONS 
  GENERAL SPECIFICATIONS 
General Protection Class:

I

Overvoltage Category:

II

Pollution Degree:

2

Ingress ProtectionIP30
Underwriters
Laboratories
File E137708
UL 60950, Third Edition
UL 2601 - 1 Second Edition
CB Report Per IEC 950 (1991)
Second Edition A1, A2, A3, A4
All EN 60950 Deviations
CB Report Per IEC 601-1-1988
First Edition, A1, A2
 
 UL 60950 Third Edition 
UL Recognition Mark for Canada
File E137708
CAN/CSA-C22.2 No. 60950-00
CAN/CSA-C22.2 No. 601-1-M90
 
TUVEN 60950:2000
EN 60601-1/A2: 1995
 
 Low Voltage Directive 
Dielectric Strength 
Reinforced Insulation5656 VDC, Primary to Secondary, 1 Sec.
Basic Insulation2121 VDC, Primary to Ground, 1 Sec.

Operational Insulation

707 VDC, Secondary to Ground, 1 Sec.
Leakage Current<300 A Earth Leakage Current
Mean Time Between Failures100,000 Hours min., MIL-HDBK-217F, 25oC, GB
Weight1.6 Lbs. 
 

ELECTROMAGNETIC COMPATIBILITY SPECIFICATIONS

Electrostatic DischargeEN 61000-4-2+/-8kV Contact Discharge
+/-8kVAir Discharge
Radiated Electro-magnetic Field EN 61000-4-380MHz-2.5GHz, 10V/m, 80% AM
EFT/BurstsEN 61000-4-4+/-2kV
SurgesEN 61000-4-5+/-1 kV Differential Mode
+/-2 kV Common Mode
Conducted ImmunityEN 61000-4-6.15-80MHz., 10V, 80% AM
Voltage Dips and IntuptionsEN 61000-4-1130% Reduction
95% Reduction
60% Reduction
95% Reduction
Radiated EmissionsEN 55011/22Class B
Conducted EmissionsEN 55011/22Class B
  Notes 
Consult factory for alternate output configuration.
Consult factory for positive, negative or floating output 2 or 3.
Refer to Application Information for complete output power ratings.

All specifications are maximum at 25C unless otherwise stated and are subjected to change without notice.
Specify optional chassis nad cover when ordering.
  MODEL LISTING
ModelOutput 1Output 2Output 3Output 4Output5
SRP-30A-4001+3.3V/3A+5V/2A+12V/.35A-12V/.35A28W
SRP-30A-4002+5V/3A+3.3V/2A+12V/.35A-12V/.35A30W
SRP-30A-4003+5V/3A-5V/2A+12V/.35A-12V/.35A30W
SRP-30A-4004+5V/3A-5V/2A+15V/.35A-15V/.35A30W
SRP-30A-4005+5V/3A+24V/.75A+12V/.35A-12V/.35A30W
SRP-30A-4006+5V/3A+24V/.75A+15V/.35A-15V/.35A30W
SRP-30A-3001+5V/3A+12V/1.5A-12V/.5A 30W
SRP-30A-3002+5V/3A+15V/1.5A-15V/.5A 30W
SRP-30A-2001+5V/3A+24V/.75A  30W
SRP-30A-2002+5V/3A+12V/1.5A  30W
SRP-30A-2003+5V/3A-5V/3A  30W
SRP-30A-2004+12V/1.5A-12V/1.5A  30W
SRP-30A-2005+15V/1.5A-15V/1.5A  30W
SRP-30A-10013.3V/9A   30W
SRP-35A-10025V/7A   35W
SRP-35A-100312V/2.9A   35W
SRP-35A-100415V/2.3A   35W
SRP-35A-100524V/1.45A   35W
SRP-35A-100648V/.73A   35W
  SRP-30/35 SERIES MECHANICAL SPECIFICATIONS 

  APPLICATIONS INFORMATION
  1. Each output can deliver its rated current but total output power must not exceed 28-35 watts depending on model.
  2. Sufficient area must be provided around convection cooled power supplies to allow natural movement of air to develop.
  3. A minimum load of 10% is required on output one to insure proper regulation of remaining outputs.
  4. Remote sense terminals may be used to compensate for cable losses up to 250mV. The use of a twisted pair is recommended as well as a decoupling capacitor (0.1 0 10F) and a capacitor of 100F/amp connected across the load.
  5. Peak to peak output ripple and noise is measured directly across a 1F ceramic capacitor at the output terminals of the power supply cord, without the use of the probe ground lead or retractable tip, 20 MHz bandwidth.
  6. This product was type tested and safety certificated using the the dielectric strength test voltages listed in Table V of UL 60601-1. In consideration of clause 20.4g, care must be taken to insure the voltage applied to a reinforced insulation does not over stress basic insulation. Secondary to ground capacitors may need to be removed prior to performing a dielectric strength type test on the end product. It is highly recommended that the DC test voltages listed in DVB.1. Annex DVB are not exceeded during a production-line dielectric strength test of the assembled end product. Please consult factory for further information.
  7. This power supply has been safety approved and final tested using a DC dielectric strength test. Please consult factory before performing AC dielectric strength test.
 
 

 Maximum Output Power vs. Ambient Temperature(30 W)

 

 Maximum Output Power vs. Ambient Temperature(35 W)

  CONNECTOR SPECIFICATION
AC InputIEC 320 AC Power Receptacle
DC Output8 pin connector mates with Power Dynamics 8 pin din socket #DS-048